Low-cost, disposable screen-printed electrodes on flexible plastic substrate for electrochemical analysis in clinical, environmental and agrifood field. Thick-film printed electrochemical sensors enable the use of small sample volume.
Standard dimensions
27.5 x 10.1 mm
Substrate
PET (white) / ceramic
Substrate thickness
350 µm
Working electrode
Single or Dual
Sample volume
20 - 50 µL
Electrode material
Carbon / Silver / Gold
Single screen-printed electrodes are based on a classical three-electrodes approach with one working electrode (WE), a reference electrode (RE) and a auxiliary electrode (AE). Low-cost solution suitable for electroanalysis, flow systems, nanotechnology or biosensor development.
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.38 mm
Substrate: Ceramic
Electrodes material: WE: C / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.38 mm
Substrate: Ceramic
Electrodes material: WE: C / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C - RE: Ag/AgCl - AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.38 mm
Substrate: Ceramic
Electrodes material: WE: C - RE: Ag/AgCl - AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: Graphene / RE: Ag / AE: Graphene
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.38 mm
Substrate: Ceramic
Electrodes material: WE: Graphene / RE: Ag / AE: Graphene
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: Graphene - RE: Ag/AgCl - AE: Graphene
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.38 mm
Substrate: Ceramic
Electrodes material: WE: Graphene - RE: Ag/AgCl - AE: Graphene
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: Au / RE: Ag / AE: Au
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.38 mm
Substrate: Ceramic
Electrodes material: WE: Au / RE: Ag / AE: Au
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box
Single screen-printed electrodes including an electroactive meadiator in the working electrode (WE) for enhancing the detection of specific target analytes. Cost-effective solution suitable for the development of enzymatic biosensors.
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C-CoPc / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Enzyme-based sensors, biosensors, hydrogen peroxide (H2O2) detection
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C-PB / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Enzyme-based sensors, biosensors, hydrogen peroxide (H2O2) detection
Contents: 50 units/box
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE: C-FeCN / RE: Ag / AE: C
WE size: 3 mm Ø (7.1 mm2)
Sample volume: 20 - 50 µL
Applications: Enzyme-based sensors, biosensors, hydrogen peroxide (H2O2) detection
Contents: 50 units/box
Dual screen-printed electrodes are based on a four-electrodes approach with two working electrodes (WE1 / WE2), sharing a reference (RE) and an auxiliary (AE) electrode. A very affordable solution suitable for the development of multiplexed chemical-sensors and bio-sensors for field analysis.
Dimensions: 27.5 x 10.1 x 0.35 mm
Substrate: PET (white)
Electrodes material: WE1/2: C / RE: Ag / AE: C
WE size: 1,0x2.5 mm (2,3 mm2 )
Applications: Electroanalysis, flow systems, nanotechnology, chemical sensors, biosensors
Contents: 50 units/box