High accuracy and quality peristaltic pumps and syringe pumps are able to satisfy the various requirements of our customers for Pharmaceutical, Medical, Environmental monitoring and Laboratory fields, etc.
LSP01-3A Single-channel Syringe Pump
Just infusion single-channel syringe pump with 5 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.
LSP01-3A Single-channel Syringe Pump
Dimensions: 280 x 210 x 140 mm (D x W x H)
Working mode: Infusion
Channels: 1
Advance per step: 0.156 µm
Linear force: > 90 N
Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance
Flow rate: 0.83 nL/min – 54.2 mL/min
Syringe size: 10 µL – 60 mL
Comm. interface: RS485
Pump stroke: 140 mm
Max. linear rate: 65 mm/min
Min. linear rate: 5 µm/min
State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction
Control signal input: Falling edge or TLL signal to control start/stop
Display: Display volume, flow rate or linear speed (128x64 graphic LCD)
Power off memory: Storing the running parameters automatically
Power supply: AC 90V-260V / 15W
Operating temperature: 0 to 40 ºC
Humidity: < 80%
Weight: 3.6 Kg
Certificates: CE, EMC, ESD ≥ Level IV (IEC 61000-4-2)
LSP01-3A
LSP01-2A Single-channel Syringe Pump
Just infusion high-precision single-channel syringe pump with 1 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.
LSP01-2A Single-channel Syringe Pump
Dimensions: 280 x 210 x 140 mm (D x W x H)
Working mode: Infusion
Channels: 1
Advance per step: 0.031 µm
Linear force: > 90 N
Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance
Flow rate: 0.16 nL/min – 10.8 mL/min
Syringe size: 10 µL – 60 mL
Comm. interface: RS485
Pump stroke: 140 mm
Max. linear rate: 13 mm/min
Min. linear rate: 1 µm/min
State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction
Control signal input: Falling edge or TLL signal to control start/stop
Display: Display volume, flow rate or linear speed (128x64 graphic LCD)
Power off memory: Storing the running parameters automatically
Power supply: AC 90V-260V / 15W
Operating temperature: 0 to 40 ºC
Humidity: < 80%
Weight: 3.6 Kg
Certificates: CE
LSP01-2A
LSP02-2B Dual-channel Syringe Pump
2-channels syringe pump with infusion/ withdrawal mode. The acceptable syringe specification is from 10 µL to 140 mL. Suitable for high accuracy and small flow rate liquid transferring. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.
LSP02-2B Dual-channel Syringe Pump
Dimensions: 280 x 250 x 140 mm (D x W x H)
Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous
Channels: 2
Advance per step: 0.156 µm
Linear force: > 180 N
Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance
Flow rate: 0.83 nL/min – 150.5 mL/min
Syringe size: 10 µL – 140 mL
Comm. interface: RS485
Pump stroke: 140 mm
Max. linear rate: 130 mm/min
Min. linear rate: 5 µm/min
State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction
Control signal input: Falling edge or TLL signal to control start/stop
Display: Display volume, flow rate or linear speed (128x64 graphic LCD)
Power off memory: Storing the running parameters automatically
Power supply: AC 90V-260V / 20W
Operating temperature: 0 to 40 ºC
Humidity: < 80%
Weight: 4.3 Kg
Certificates: CE, EMC, ESD ≥ Level IV (IEC 61000-4-2)
LSP02-2B
TJ-3A Single-channel Syringe Pump
Infusion/withdrawal single-channel syringe pump. The acceptable syringe specifications are from 10 µL to 60 mL. Suitable for high accuracy and small flow rate liquid transferring. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.
TJ-3A Single-channel Syringe Pump
Dimensions: 170 x 108 x 70 mm / 245 x 100 x 95 mm (controller / drive unit) (D X W X H)
Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous
Channels: 1
Advance per step: 0.165 µm
Linear force: > 90 N
Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance
Flow rate: 0.139 µL/min – 52.9 mL/min
Syringe size: 1 - 60 mL
Comm. interface: RS485
Pump stroke: 90 mm
Max. linear rate: 79.4 mm/min
Min. linear rate: 7.9 µm/min
State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction
Control signal input: Falling edge or TLL signal to control start/stop
Display: Display volume, flow rate or linear speed (128x64 graphic LCD)
Power off memory: Storing the running parameters automatically
Power supply: AC 90V-260V / 10W
Operating temperature: 0 to 40 ºC
Humidity: < 80%
Weight: 0.8 Kg (controller) 1.3 Kg (drive unit)
Certificates: CE