LSP01-1A Single-channel Syringe Pump

LSP01-3A Single-channel Syringe Pump

Just infusion single-channel syringe pump with 5 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP01-3A Single-channel Syringe Pump

Dimensions: 280 x 210 x 140 mm (D x W x H)

Working mode: Infusion

Channels: 1

Advance per step: 0.156 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.83 nL/min – 54.2 mL/min

Syringe size: 10 µL – 60 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 65 mm/min

Min. linear rate: 5 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 15W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 3.6 Kg

Certificates: CE, EMC, ESD ≥ Level IV (IEC 61000-4-2)

LSP01-3A

LSP01-2A Single-channel Syringe Pump

LSP01-2A Single-channel Syringe Pump

Just infusion high-precision single-channel syringe pump with 1 µm/min minimum linear speed. The acceptable syringe specification is from 10 μL to 60 mL. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP01-2A Single-channel Syringe Pump

Dimensions: 280 x 210 x 140 mm (D x W x H)

Working mode: Infusion

Channels: 1

Advance per step: 0.031 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.16 nL/min – 10.8 mL/min

Syringe size: 10 µL – 60 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 13 mm/min

Min. linear rate: 1 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 15W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 3.6 Kg

Certificates: CE

LSP01-2A

LSP02-2B Dual-channel Syringe Pump

LSP02-2B Dual-channel Syringe Pump

2-channels syringe pump with infusion/ withdrawal mode. The acceptable syringe specification is from 10 µL to 140 mL. Suitable for high accuracy and small flow rate liquid transferring. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

LSP02-2B Dual-channel Syringe Pump

Dimensions: 280 x 250 x 140 mm (D x W x H)

Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous

Channels: 2

Advance per step: 0.156 µm

Linear force: > 180 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.83 nL/min – 150.5 mL/min

Syringe size: 10 µL – 140 mL

Comm. interface: RS485

Pump stroke: 140 mm

Max. linear rate: 130 mm/min

Min. linear rate: 5 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 20W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 4.3 Kg

Certificates: CE, EMC, ESD ≥ Level IV (IEC 61000-4-2)

LSP02-2B

TJ-3A Single-channel Syringe Pump

TJ-3A Single-channel Syringe Pump

Infusion/withdrawal single-channel syringe pump. The acceptable syringe specifications are from 10 µL to 60 mL. Suitable for high accuracy and small flow rate liquid transferring. Compatible with AIO-Cell, Flow-cell and TL add-ons, and thin-film electrodes.

TJ-3A Single-channel Syringe Pump

Dimensions: 170 x 108 x 70 mm / 245 x 100 x 95 mm (controller / drive unit) (D X W X H)

Working mode: Infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous

Channels: 1

Advance per step: 0.165 µm

Linear force: > 90 N

Accuracy: ≤ ± 0.5% error in the condition of > 30% of max. infusion distance

Flow rate: 0.139 µL/min – 52.9 mL/min

Syringe size: 1 - 60 mL

Comm. interface: RS485

Pump stroke: 90 mm

Max. linear rate: 79.4 mm/min

Min. linear rate: 7.9 µm/min

State signal output: 2 output signals (OC gate signal) to indicate start/stop and direction

Control signal input: Falling edge or TLL signal to control start/stop

Display: Display volume, flow rate or linear speed (128x64 graphic LCD)

Power off memory: Storing the running parameters automatically

Power supply: AC 90V-260V / 10W

Operating temperature: 0 to 40 ºC

Humidity: < 80%

Weight: 0.8 Kg (controller) 1.3 Kg (drive unit)

Certificates: CE

TJ-3A/W0109-1B

28 Products. View all

Returns

All the information that you should know about our returns policy...

More information

Contact

Contact us to solve your doubts or answer your questions. We can help you!

More information

Delivery

We ship the products under strict security measures, ensuring their protection...

More information

subscribe to our monthly newsletter